JP6501
PINS |
SETTING |
DESCRIPTION |
1-2 |
Out |
Disable TERMPWR to bus |
1-2 |
In |
Enable TERMPWR to bus |
|
|
JP6503
SCSI ID |
3 |
2 |
1 |
0 |
Out |
Out |
Out |
1 |
Out |
Out |
In |
2 |
Out |
In |
Out |
3 |
Out |
In |
In |
4 |
In |
Out |
Out |
5 |
In |
Out |
In |
6 |
In |
In |
Out |
|
|
SW6501
SWITCH |
SETTING |
DESCRIPTION |
1 |
Off |
Enable SCSI ID 0 = 20 |
2 |
Off |
Enable SCSI ID 1 = 21 |
3 |
Off |
Enable SCSI ID 2 = 22 |
4 |
On |
Enable SCSI-2 mode |
5 |
On |
Enable parity |
6 |
Off |
Enable data compression |
7 |
Off |
Reserved for factory use |
8 |
On |
Enable power-on self test |
|
|
LMJB0178 PCB |
|
|
|
S1 |
SWITCH |
SETTING |
DESCRIPTION |
1 2 |
Off* Off* |
English language display |
1 2 |
Off On |
French language display |
1 2 |
On On |
Spanish language display |
1 2 |
On Off |
German language display |
3 3 |
Off On* |
Stop after last tape
Restart at Tape 1 after last tape |
4 4 |
On* Off |
High intensity display
Low intensity display |
5 |
On* |
Enable power-on self test |
6 |
Off |
Not used |
7 |
Off |
Not used |
* Default settings
|
|
|
Auto-Loader |
|
|
S5 |
SWITCH |
SETTING |
DESCRIPTION |
1 |
Off* On |
Horizontal character display
Vertical character display |
2 |
Off On* |
Do NOT load tape on power-up
Load tape on power-up |
3 |
Off |
Reserved |
4 |
Off |
Reserved |
* Default settings
|