Comments and Suggestions
   
Last updated: November 26, 1999


Maxtor LXT-213SY (207MB)

3 1/2" 3600 RPM Single Ended SCSI
Sun-4/40/50/75 / SS10

Option 553

370-1327
1 5/8" Height

JUMPER SETTING DESCRIPTION USAGE
A0,A1,A2 Out Drive ID Target 0
A0 In Drive ID Target 1
A1 In Drive ID Target 2
A0,A1 In Drive ID Target 3
WS In Wait spin Spin with power
EP In Parity Enable parity
TP Out TERMPWR Disable TP

Power

0.6 Amps @ +5Vdc
0.6 Amps @ +12Vdc
10.2 Watts

Notes

  1. The Sun-4/60/65 chassis does not provide adequate cooling for the 207MB Disk Drive.
  2. This drive is not supported inside the Desktop Storage Pack due to the orientation of the address jumpers.
  3. The SS10 requires minimum Firmware 4.22 (370-1327-04 Rev 52).

References

  1. SPARCstation IPC Installation Guide, 800-5037-10.Internet Link
  2. SPARCstation IPC Installation Guide, 800-5565-10.Internet Link
  3. Installing SPARCstation 2 Internal Disk Drives, 800-5661-10.Internet Link


© 1987-2000, Sun Microsystems Inc.